| SPECIFICATIONS |
| COLLECTOR (Panel) | |
Trim & Frame Materials: |
Finished 27 mil Aluminum Trim and
Frame = Total 54 mil (1.37 mm). 26 Trim Colors |
Absorber Material: |
Black Crystal Coated Copper Fin to 1/2" OD Copper tubing
with unions. |
Glazing: |
.236" (6.0mm) Twinwall Polycarbonate UV Treated. |
Dimension / Weight: |
20-01 - 144.3" 10-01 - 72.15 x 20" x 3"; 38 lbs. (3.67 m x 0.51 m x 0.076 m 17.24 Kg) 18.4 Net s/f (1.71 m2) 10-01 - 72.15 x 20" x 3"; 19lbs. (1.84 m x 0.51 m x 0.076 m 17.24 Kg) 9.2 Net s/f (.86 m2) |
Fluid Capacity: |
20-01 = .3 Gallons / 10-01 = .15 Gallons |
Recommended Flow Rates: |
.20 to .35 GPM (0.946 to 1.324 L/min) |
Maximum Working Pressure: |
150 PSI (10.21 atm) |
| Maximum Stagnation Temp: |
250 degrees F (121.11 degrees C) |
| Heat Transfer Fluid: |
Potable water or Propylene glycol |
Standard Components: |
Mounting rails, mounting brackets, tech screws and lags |
Colors: Standard Color: Musket Brown (Cl01) / Dove Gray (C109) free option |
|
Full Custom Color Option Chart: Raffia Beige, Texas Ivory, W. Bronze, Navajo and Satin White are not available |
|
Optional Colors Include: Colonial (light) Gray (CO102), Tahoe Blue (Col03), Colonial Red (Col04), Forest Green (Col05), White (Col06), Buckskin Brown (CO107), Beaver (medium) Brown (CO108), C.B. (medium) Blue (CO110), Spanish Green (CO111), Storm/Slate (dark) Gray (CO112), Royal Brown (CO113), Ivory (CO114), Sea Blue (CO115), Leaf Green (CO116), Pebblestone Clay (CO117), Woodbeige (CO118), Peach (great on many light orange tile roofs) (CO119), Almond (CO120), Black (CO121), Adobe Tan (CO121), Classic Cream (CO122), Bronze (CO123), Heritage Cream (CO124), Marine Green (CO125). |
|
|
|
|
| Rail and Ell Bracket | Ell Bracket to Collector | Easy Compression Connections |
| PV POWERED PUMP (option) | |
PV Panel: |
9 - 32 Watt, 12 Volt DC depending on system |
Circulator: |
12 Volt - "El Sid", 12 Volt Hartell or equal .
|
| OPEN LOOP FREEZE PROTECTION (Optional) | |
Type: |
Thermal Bleed Valve |
| For light freeze protection down to 30F |
Temperature to start to open: 40 degrees F. |
Type: |
Recirculation Built in or with 40F Freeze Snap Switch for 12 Volt |
| For 110 Volt Differential Controller or with 12 Volt Circulator with Transformer for light freeze protection down to 30F. | |
| CONNECTING LINES & INSULATION (standard) | |
Tubing: |
1/2" (12.7 mm) OD copper - 50' (15.24 m) |
Insulation [6' (1.83 m) High Temp.supplied] |
1/2" (12.7mm) ID 1/2" (12.7 mm) or 3/4" (19.05 mm) wall |
| TUBING CONNECTION METHODS (standard) | |
| Type: |
1/2" Outside Diameter Brass Compression Union. |
| STORAGE TANK (Not Supplied) | |
Standard Connections: |
Open Loop: Use Existing 50 gal (189.27 L) -- 120 gal (454.25 L) tank |
Closed Loop Heat Exchanger: |
Closed Loop: Optional 80 Gallon 81V080HE1 Rheem/Rudd Heat Exchanger Tank (Required for OG300 System 5). Optional for System 4: Power Rod or HotRod, use existing or added 50 - 120 gal. tank |
| CONTROL (standard - non freeze application) | |
| Type: | System 1 = 110 Degree Snap Switch (PV Optional) |
| Type: | System 2 and 4 = Differential Controller System 3 and 5 = PV Panel |
| DIFFERENTIAL CONTROL DETAIL | |
- System 2 and 4 with standard 110V circulator Required with heat exchanger using standard 110V circulator - 40F Freeze Snap switch for light freeze protection down to 30F -- |
|
Type: |
Independent Energy or Equal |
Sensors: |
Two 10 K Sensors with wire |
Turn on Differential: |
8 - 24 F (Avg. set 12 F) |
Turn off Differential: |
4 F (fixed) |
Recirculate turn on: |
40 F (3.33 C) |
Storage High Limit: |
110 - 230 F - Set at 180 F (82.2 C) |
Power Requirements: |
105 - 120VAC, 50/60hz, |
Output power: |
115VAC, 1/3HP (248.56 W) |
Home | Sitemap | Going
Solar | Solar Savings | Ordering | Brochures | Technical | Q & A | History & Links | Dealerships |
Page Updated on: June 20, 2006